HELUKAT® 600LAN CAT.7e S/FTP FRNC STATIC violet 4 x 2 x AWG 23 /1
Part no. 80810
- Cat. 7e
Item Details
- Part no.
- 80810
- Item description
- HELUKAT® 600LAN CAT.7e S/FTP FRNC STATIC violet 4 x 2 x AWG 23 /1
- Sheath colour
- violet (RAL 4005)
- Cross-sec. mm² (approx.)
- 0.26
- Conductor Ø mm (approx.)
- 0.57
- Core Ø mm (approx.)
- 1.4
- Outer Ø mm (approx.)
- 7.3
- Cu factor per km
- 28.0
- Weight kg/km (approx.)
- 55.0
- Copper base in EUR / 100 kg
- 100
- CPR class
- Dca
- Metres per Packaging Unit
- 100, 500, 1000
- Cut-to-length service available
- yes
- EAN / GTIN
- 4060892313905
- Customs tariff number
- 85444920
Technical Data
| LAN cable / Cat. 7e acc. to ISO/IEC 11801, DIN EN 50173, IEC 61156-5, DIN EN 50288-4-1 | |
| Temperature range | fixed installation -20°C to +60°C during installation 0°C to +50°C |
| Peak operating voltage | 125 V (not for high power current installation purposes) |
| Test voltage | 700 V |
| Conductor resistance at 20°C | max. 77.0 Ohm/km |
| Loop resistance at 20°C | max. 154.0 Ohm/km |
| Mutual capacitance core/core | at 800 Hz, approx. 48 pF/m |
| Rel. Velocity of Propagation | approx. 79% |
| Characteristic impedance | at 1 to 100 MHz, 100 Ohm ± 15 Ohm at 101 to 1000 MHz, 100 Ohm ± 20 Ohm |
| Caloric load | approx. 0.60 MJ/m |
| Minimum bending radius | flexible 8x Outer-Ø fixed 4x Outer-Ø |
Details
Cable Structure
-
- Copper conductor bare, AWG sizes
-
- Core insulation: Foam PE
-
- Core identification: colour coded, pairs:
- No. 1: white / blue
- No. 2: white / orange
- No. 3: white / green
- No. 4: white / brown
-
- Cores stranded in pairs with optimal lay lengths
-
- Screening element: pairs, plastic-coated aluminium foil (St)
-
- Screen: braided screen of tinned copper wires
-
- Outer sheath: halogen-free, flame retardant compound (FRNC)
-
- Length marking: in metres
Properties
-
- halogen-free
-
- flame-retardant
Tests
-
- halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
-
- corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- bundle fire test acc. to DIN VDE 0482-332-3 / DIN EN 60332-3 / IEC 60332-3
-
- smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
-
- CPR class: Dca
-
- certifications and approvals:
- CC-Link IE
Notes
-
- Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
Application
-
- Data cable for structured cabling systems with generous headroom and outstanding performance, for use in the tertiary and secondary areas of networks. Its special mechanical properties and optimised construction allow for easy installation.